Permit: T01CM06161

Parcel: 110065810

Inspection Status: Approved

Inspection History: SHEET ROCK NAILING

Permit Number - T01CM06161

Inspection Description - SHEET ROCK NAILING

Inspection Status - Approved

Date Description Inspector Results Comments
03/01/2002 SHEET ROCK NAILING Approved IVRS - Inspection 0000*
02/28/2002 SHEET ROCK NAILING Denied IVRS - Inspection 0999*1.) PLAN CALLS FOR 6 D NAILS IN SHEAR WALLS 1 1/4 SCREWS USED. YOU MUST USED NAILS OR REVISE PLAN FOR USE OF SCREW. SCREWS MUST COMPLY WITH IRC TABLE 602.3L1 AND YOU MUST PROVIDE ICBO LISTING FOR SCREW USED