Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/06/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 02/05/2002 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) REMOVE SCREEN FROM DRYER VENT 2) REMOVE NAILS FROM JOISTS TO TRUSSES AT PATIO CONNECTION 3) OK TO INSULATE |
| 02/01/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) NO WATER TEST ON TOP OUT 2) PROVIDE OR REPLACE ENGINEERING FOR NOTCHED BEARING WALLS 3) REMOVE SCREEN FROM DRYER VENT 4) ADD STUD LEFT OR RIGHT SIDE OF HOOD VENT 5) ADD 16 GAUGE STRAP WITH 6-16D NAILS EACH SIDE AT KITCHEN 6) REMOVE NAILS FROM PORCH JOIST TO TRUSSES AND INSTALL H2.5 AS PER DETAIL #6 PG A8 7) PROVIDE DETAIL SHOWING INTERIOR WALLS NAILING TO BOTTOM TRUSS CHORD 8) PROTECT COPPER WATER LINES AT LAUNDRY ROOM 9) PEX WATER |