Permit: T01CM06116

Parcel: 141305790


Addresses:

10517 E OAKBROOK ST


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T01CM06116

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
02/11/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
02/06/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) HUS 26 HANGERS MUST BE NAILED AT 45 DEGREE ANGLE WITH 16D SINKERS 2) STRAP CORNERS THAT ARE NOT CABIN TIED 3) SHEARWALL INTERSECTION MUST BE BUILT PER DETAIL (10/SD4) 4) SHEAR TRANSFER TO TRUSS MUST BE PER DETAIL (6A/SD3) 5) MAXIMUM ANGLE FOR HINGE BRACING IS 45 DEGREE SEE DETAIL (7/SD3) 6) OVERBUILD CALLS FOR 2 X 8 VALLEY PLATE