Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T01CM06111
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/14/2002 | FRAMING | Approved | IVRS - Inspection 0000* | |
02/13/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) MANY BLOCKS MISSING 2) INSTALL FHA STRAPS AT OVER DRILLED TOP PLATE OF SHEARWALL #5 3) INSTALL COIL STRAP AT END OF PATIO BEAM 4) FIRESTOP AT DOUBLE WALLS IN MASTER BATH 5) TIGHTEN NUTS ON HD BOLTS 6) INSTALL H2.5'S AT PATIO JOISTS 7) ANCHOR PATIO ROOF LEDGER PER PLAN 8) SEHAR PANELS MUST BE NAILED THROUGH ROOF SHEATHIN PER PLAN 9) AB MISSING NUT AND WASHER 10) TIGHTEN ALL AB'S AND REDHEADS |