Permit: T01CM06109

Parcel: 141171480


Addresses:

8413 S BURIEN RD


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T01CM06109

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
02/06/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
02/05/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) 2 OUTSIDE TRUSS CLIPS MISSING 2) STUD CLIPS NOT NAILED 3) STRAP/CLIP TRUSS AT PATIO TO WALL 4) STRAP ALL NON-CABIN TIED EXTERIOR TOP PLATES 5) DETAIL DT1/5 SHEARWALL CONNECTION NOT DONE 6) BLOCK FRONT ENTRY COLUMN OR ADD 2ND ANCHORS 7) NAIL BIRD BOARDS 8) OSB ROOF SHEATHIN MUST COVER 2 BAYS OR BE BLOCKED 9) HOLDOWNS MUST ATTACH TO KING STUDS ONLY