Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/14/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 04/09/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) FIRE BLOCK MISSING THRU-OUT 2) CROSS BRACE TRUSSES AT ENDS AND 25 ON CENTER MAX 3) POSITIVE CONNECTION REQUIRED AT TOP CHORD OF JACK TRUSSES 4) SEAL UNDER TUB OVER FLOW 5) STRAP CROSS KITCHEN EXHAUST AND DUCT 6) PROVIDE CONNECTION AS REQUIRED (SHEET 4) HIP GIRDER TO GIRDER TRUSS 7) BATH GFI OUTLETS SHALL NOT HAVE OTHER FIXTURES |