Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T01CM06094
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/14/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
| 04/09/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) FIRE BLOCK MISSING THRU-OUT 2) CROSS BRACE TRUSSES AT ENDS AND 25 ON CENTER MAX 3) POSITIVE CONNECTION REQUIRED AT TOP CHORD OF JACK TRUSSES 4) SEAL UNDER TUB OVER FLOW 5) STRAP CROSS KITCHEN EXHAUST AND DUCT 6) PROVIDE CONNECTION AS REQUIRED (SHEET 4) HIP GIRDER TO GIRDER TRUSS 7) BATH GFI OUTLETS SHALL NOT HAVE OTHER FIXTURES |