Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 10/08/2002 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000* |
| 07/16/2002 |
PLUMBING - ROUGH, SOIL |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) ALLIN HOUSE AND ADDITION OK 2) CLEANOUTS AND SEWER CONNECTION NOT MADE 3) OK TO COVER ALL WEST OF EAST WALL |
| 07/12/2002 |
PLUMBING - ROUGH, SOIL |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) ROUGH PLUMBING FOR WEST ADDITION OK TO COVER BUT SEWER DRAIN UNDER EXISTING BUILDING HAS 180 DEGREES OF HORIZONTAL CHANGE. MAXIMUM HORIZONTAL CHANGE WITHOUT CLEANOUTS IS 135 DEGREES PER UPC SECTION 719.1 |
| 07/10/2002 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*/ 1) HORIZONTAL SAYS YOUR PHONE SERVICE IS DISCONNECTED UNABLE TO CALL YOU 2) NO CHANGE FROM PRIOR INSPECTION 3) NEXT FAILURE MAY BE CHARGED A REINSPECTION FEE |
| 07/08/2002 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999* |