Permit: T01CM06066

Parcel: 12009001B


Addresses:

420 E AVIATION DR

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
12/15/2003 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*/ MEDIUM PRESSURE REGULATOR IS OK. VENT THRU ROOF IS OK.
12/03/2003 PLUMBING - GAS PRESSURE TEST Denied 1) MEDIUM PRESSURE SYSTEM REQUIRES 60 POUNDS OF AIR PRESSURE TEST SEE SECTION 1204.3.2, 94 UPC 2) MUST REMOVE REGULATOR AND UNION IN LINE FOR WATER HEATER AND RETEST SYSTEM 3) LOCATE GAS PRESSURE TEST GUAGE AT WATER HEATER TO VERIFY TEST 4) MUST PLUG OR CAP ANY VALVES THAT ARE NOT CONNECTED TO EQUIPMENT