Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/09/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 04/03/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) NAIL PROTECTION REQUIRED FOR ELECTRIC 2) BATH GFCI REQUIRES TO BE ON IT'S OWN SEPARATE CIRCUIT 3) ELECTRIC NOT COMPLETE IN LAUNDRY ROOM 4) WIRING FOR RANGE REQUIRES TO BE INSTALLED IN BOX CORRECTLY 5) SECURE WIRE AT BATH SWITCH 6) SMOKE DETECTOR TO BE 36" FROM MECH OUTLET |
| 03/25/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) STRAP AT RANGE HOOD VENT 2) BATHROOM CIRCUIT SHALL BE ON SEPERATE GFCI CIRCUIT 3) ELECTRIC WIRING NOT COMPLETE 4) MECHANICAL REGISTERS BLOCKS REQUIRED AT 3 SIDES 5) NAIL PROTECTION REQUIRED FOR ELLECTRIC AND PLUMBING BORED HOLES 1 1/4 FROM EDGE 6) 10' HEAD OF WATER TEST ON ROUGH PLUMBING 7) STRAP BEAM TO KING STUDS 8) ELECTRIC WIRING RUNS REQUIRE TO BE PROTECTED AT CARPORT CEILING |