Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/28/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 02/25/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) NOT READY |
| 02/15/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) EXTERIOR SHEATHING DOES NOT EXTEND TO AND IS NOT NAILED TO DOUBLE TOP PLATES. H2.5 CLIPS WILL HAVE TO BE INSTALLED ON THE INTERIOR OF THE HOUSE FROM THE STUDS TO THE DOUBLE TOP PLATE OR RELOCATE THE OSB UP AND PUT THE RIPPER IN THE MIDDLE 2) STUCCO WEEP SCREED INSTALLED UNABLE TO TELL IF OSB SHEATHING IS NAILED TO BOTTOM PLATES 3) TRUSSES REQUIRE CROSS BRACING AT EACH END AND EVERY 25 FEET 4) LAUNDRY ROOM ROOF AND CARPORT NOT FRAMED 5) SHEATHING ENDS AND EDGES MUST LAND ON FRAMING MEMBERS 6) UNTREATED WOOD NOT ALLOWED IN CONTACT WITH CONCRETE 7) OSB ROOF SHEATHING MUST SPAN 3 TRUSSES (2 BAYS)-2 X PANEL NOT ALLOWED |