Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 08/07/2002 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000*1.) CORRECTIONS MADE OK 2.) GAS TEST OK 3.) OK TO COVERS WALLS 4.) CLOSET FLANGES OK 5.) TUBS OK. |
| 08/06/2002 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*1.) SEE NOTE #2 ABOVE. 2.) YOU HAVE CHANGED THE TRAP ARM AT THE KITCHEN SINK WHERE IS THE WATER TEST? 3.) NO PORTION OF ANY WORK MAY BE CONCEALED UNTIL AT HAS BEEN INSPECTED AND APPROVED. YOU DID NOT RECIEVE PERMISSION TO COVER ANY WORK REMOVE INSUALTION SO INSPECTION CAN BE COMPLETED. |
| 08/02/2002 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*1.) PRESSURE TEST 10LBS OR LESS REQUIRE A GUAGE IN 1/10TH INCREMENT. PRESSURE TEST 10# 100# REQUIRE GUAGES IN ONE POUND INCREMENTS 2.) HORIZONTAL HORIZONTAL CHANGE OF DIRECTION TO BE WYE BRANCH FITTING OR EQUIVILENT. 3.) A SANTEE MAY NOT LAY ON ITS SIDE A CLEAN OUT IS TO BE INSTALLED ABOVE THE FLOW LINE. |