Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - CABLE DROP
Permit Number - T01CM05961
Inspection Description - ELECTRIC - CABLE DROP
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/18/2006 | ELECTRIC - CABLE DROP | Approved | IVRS - Inspection :* | |
| 12/06/2006 | ELECTRIC - CABLE DROP | Denied | IVRS - Inspection : The service is not per code.| 210* 1. INSTALL PROPER SIZE BONDING CONDUCTORS FOR SERVICE RACEWAYS -- NEC 250.102(C) 2. INSTALL ADDRESS ON SERVICE 3. IDENTIFY ALL SERVICE DISCONNECTS AND UNIT NUMBERS NEC 230.70(B) 4. GO THROUGH AND RE-TORQUE ALL SCREWS -- NEC 110.3 5. PROVIDE PLAQUE CONCERNING BRANCH CKTS OTHER THAN THOSE SUPPLIED BY SERVICE DISCONNECTS, IE FIRE BELL, LIGHTING, ETC. 6. CHECK UFER |
|
| 09/26/2006 | ELECTRIC - CABLE DROP | Not ready for Inspection | IVRS - Inspection :* |