Permit: T01CM05943

Parcel: 141112610

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T01CM05943

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
03/11/2002 FRAMING Approved IVRS - Inspection 0000*
02/27/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) FHA STRAP REAR GARAGE TOP PLATES AT PLUMBING VENT 2) ADD STUD SHOES TO OVER BORED STUDS IN REAR GARAGE WALL 3) TIGHTEN ANCHORS AT GARAGE FRONT 4) NO WATER PRESSURE OR DRAINAGE TEST 5) FHA STRAP TOP PLATE IN MASTER BATH AND CRIPPLES 6) MOVE PEX FROM CAN LIGHT IN KITCHEN 7) BLOCK KITCHEN DUCT BOOT 8) CORRECT NEGATIVE PITCH ON CONDENSATE LINES 9) FHA STRAP FRONT LEFT BED BOTTOM PLATE AT PLUMBING VENT 10) SHIM HEADERS WHERE NEEDED 11) NO OUTLET IN SOUTH HALL BATH 12) EXTEND MECHANICAL PLATFORM TO NORTHSIDE 13) CLEAR COMBUSTIBLES FROM NORTH FLUE 14) ADD FLUE ESCUTCHEN TO HOT WATER FLUE AT ROOF