Permit: T01CM05926

Parcel: 141146970


Addresses:

9336 E MARCASITE LN

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
02/01/2002 FRAMING Approved IVRS - Inspection 0000*
01/31/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*
01/30/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) FHA STRAP TOP PLATES AT HOME RUNS
01/28/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) TOP PLATE HOLES FOR HOMERUNS NEED FHA STRAP-INSIDE AND OUTSIDE 2) MOVE BOTTOM 90 DEGREE OF DRYER DUCT OUT 3) SHIM HEADERS WHERE NEEDED 4) BANG PLATE MASTER TOILET VENT AT TOP PLATE 5) CORRECT INTERIOR BEARING POINTS OF TRUSS OVER LIVING ROOM INTERIOR DOOR ARCH 6) ADD RED HEAD AT ANCHOR UNDER FRONT WINDOW
01/24/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*