Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T01CM05896

Parcel: 12416023A


Addresses:

1036 S EUCLID AV

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
02/14/2002 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*1.) ALL CORRECTIONS MADE OK 2.) ABS DWV OK WATER TEST OK 3.) COPPER OK PRESSURE TEST OK 4.) OK TO COVER WALLS.
02/13/2002 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*1.) REVIEW 712.2 WATER TEST 94UPC ALL PIEP AND EVERY FITTING IN THE BLDG NEEDS TO BE TESTED (OR PORTION IN YOUR SCOPE OF WORK.)
02/11/2002 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*1.) THERE IS NO UNDERSLAB ON THIS CONTRACT, ALL WORKS IS ABOVE GRADE 2.) THE POINT OF VENT MAY NOT BE BELOW THE WEIR OF THE TRAP 3.) A TRAP MUST BE THE SAME SIZE AS THE TRAP ARM TO WHICH IT IS CONNECTED. 4.) A N/H" BAND IS NOT APPROVED FOR ABS. 5.) NO WATER TEST ON ABS 6.) HAVE PLUMBER CHECK ALL WORK.