Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 02/14/2002 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000*1.) ALL CORRECTIONS MADE OK 2.) ABS DWV OK WATER TEST OK 3.) COPPER OK PRESSURE TEST OK 4.) OK TO COVER WALLS. |
| 02/13/2002 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*1.) REVIEW 712.2 WATER TEST 94UPC ALL PIEP AND EVERY FITTING IN THE BLDG NEEDS TO BE TESTED (OR PORTION IN YOUR SCOPE OF WORK.) |
| 02/11/2002 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*1.) THERE IS NO UNDERSLAB ON THIS CONTRACT, ALL WORKS IS ABOVE GRADE 2.) THE POINT OF VENT MAY NOT BE BELOW THE WEIR OF THE TRAP 3.) A TRAP MUST BE THE SAME SIZE AS THE TRAP ARM TO WHICH IT IS CONNECTED. 4.) A N/H" BAND IS NOT APPROVED FOR ABS. 5.) NO WATER TEST ON ABS 6.) HAVE PLUMBER CHECK ALL WORK. |