Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T01CM05883
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/07/2002 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection 0000* | |
02/05/2002 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999*/ 1) WATER HEATER TEMP/PRESSURE RELIEF LINE MUST EXHAUST OUTSIDE AND DOWN 2) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF STUD SURFACE 3) COPPER PLUMBING CANNOT BE IN CONTACT WITH GALVANIZED PIPE USE BRONZ CONNECTOR 4) LAUNDRY TRAP CANNOT BE MORE THAN 18" ABOVE FLOOR TO WIER OF TRAP 5) LAUNDRY TRAP MUST BE 2 PIPE DIAMETERS TO VENT 6) ELECTRICALLY BOND GAS LINE WITH #4 COPPER CONDUCTOR FROM SERVICE PANEL TO AN EXPOSED CONNECTOR ON GAS PIPE 7) 11 BEARING STUDS OVER NOTCHED FOR GAS LINE INSTALL FHA 9 STRAPS WITH 6-16D NAILS EACH SIDE |