Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/24/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 01/23/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) SEE LAST INSEPCTIONS-NUMBERS 3 AND 8 NOT DONE |
| 01/18/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) TIGHTEN ANCHORS/REDHEADS 2) DRAINAGE NOT TOPPED OUT 4) WRONG STRAPS USED ON UPPER SHEARWALL AT LAUNDRY TUB VENT 5) STRAP TOP PLATES AT MASTER TOILET VENT 6) BANG PLATE STUD AT KITCHEN HORIZONTAL VENT AND TOP PLATE AND AT FRIDGE WATER SUPPLY STUD 7) CORRECT OVERNOTCHS OF KITCHEN BEARING WALL STUDS AND LAUNDRY WALL 8) REPLACE FIREBLOCK NEXT TO STOVE VENT AND DINING WALL |