Permit: T01CM05843

Parcel: 141147010


Addresses:

9360 E MARCASITE LN

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/24/2002 FRAMING Approved IVRS - Inspection 0000*
01/23/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) SEE LAST INSEPCTIONS-NUMBERS 3 AND 8 NOT DONE
01/18/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) TIGHTEN ANCHORS/REDHEADS 2) DRAINAGE NOT TOPPED OUT 4) WRONG STRAPS USED ON UPPER SHEARWALL AT LAUNDRY TUB VENT 5) STRAP TOP PLATES AT MASTER TOILET VENT 6) BANG PLATE STUD AT KITCHEN HORIZONTAL VENT AND TOP PLATE AND AT FRIDGE WATER SUPPLY STUD 7) CORRECT OVERNOTCHS OF KITCHEN BEARING WALL STUDS AND LAUNDRY WALL 8) REPLACE FIREBLOCK NEXT TO STOVE VENT AND DINING WALL