Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM05782

Parcel: 141147710

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
01/18/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
01/17/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) SEE LAST INSPECTION SHEET 2) NUMBERS 1, 4, 5 AND 6 NOT DONE
01/16/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) INSTALL 2 PIECES OSB ON EAST PLANE WITH CORRECT SIDE UP 2) BLOCK OSB AT MECHANICAL FLUE PROTRUSION 3) BOTTOM ROW OF ROOF OSB NOT NAILED ON WEST PLANE 4) STRAP FRONT ENTRY HEADER TO TOP PLATES 5) STRAP FRONT DOOR HEADER 6) STRAP COMMON RAFTER TO ROOF TRUSS ON SOUTH SIDE OF GARAGE