Permit: T01CM05779

Parcel: 13339043B


Addresses:

1122 S LELAND DR

Inspection Status: Partial Approval

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
04/01/2002 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) NEED 16D COMMON NAIL WERE THEY ARE CALLED FOR, NOT N16, YOU NEED THE LENGTH FOR THE SHEAR NAILING 2) INSTALL ALL T-BRACES FOR TRUSS CHORDS INDICATED ON SHOP DRAWINGS 3) GIRDER TRUSS #T-30 REQUIRED 2 T-BRACES 4) WHERE HANGER REQUIRES 16D IT MUST BE A SIMPSON SS16D, OR A 16D COMMON NAIL 5) PLAN CALLS FOR SIMPSON GIRDER-TO GIRDER HANGER, ALPINE TYPE USED, NEED HANGER EQUIVALANCE 6) HOUSE HAS BEEN SHEAR PLY AT ALL WALLS, PAS INSTALLED OK TO COVER