Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T01CM05762
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/08/2002 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
01/04/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) PA STRAPS MISSING 2) INSTALL PROTECTION PLUMBING PENETRATIONS EXTERIOR WALLS 3) 2 NAILS REQUIRED TOP AND BOTTOM BRACING 4) LAP BRACING SPLICES MINIMUM 2 STUD BAYS/3 STUDS |