Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/08/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 01/04/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) PA STRAPS MISSING 2) INSTALL PROTECTION PLUMBING PENETRATIONS EXTERIOR WALLS 3) 2 NAILS REQUIRED TOP AND BOTTOM BRACING 4) LAP BRACING SPLICES MINIMUM 2 STUD BAYS/3 STUDS |