Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T01CM05730
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/17/2001 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection 0000* | |
12/13/2001 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection 0999*/ 1) SANITARY "T" FITTINGS NOT ALLOWED FOR USE IN HORIZONTAL DRAIN 2) VENT FOR SHOWER IMPROPERLY INSTALLED VENT FITTING MUST BE INSTALLED ABOVE THIS CENTER LINE OF THE DRAIN 3) MUST HAVE 10 FOOT WATER COLUMN TEST 4) NO PLANS ON SITE |