Permit: T01CM05730

Parcel: 123112400


Addresses:

1243 E WAVERLY ST


Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T01CM05730

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
02/11/2002 BUILDING - FINAL Approved IVRS - Inspection 0000*
02/07/2002 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) FOR ITEM # 3090 PLUMBING FINAL; W.H. REMOVE FLEX LINE TO TPRV DISCHARGE LINE INSTALL RIGID COPPER. INSTALL PIPING WITH A 1/4" PER FT. MINIMUM SLOPE DOWNWARD FOR DRAINAGE. 2) FOR ITEM # 2090 ELECTRIC FINAL; ON WATER HEATER: WIRING MUST BE PROTECTED IN FLEX CONDUIT. AT BREAKER PANEL: IDENTIFY WATER HEATER WIRING WITH RED TAPE (WHITE WIRE)