Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 02/14/2002 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*1.) ALL CORRECTIONS MADE OK 2.) PLUMBING FINAL OK 3.) OK FOR C OF O PENDING ANY OTHER INSPECTIONS. |
| 02/13/2002 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) H.C. WATER CLOSETS REQUIRE FLUSH HANDLE ON LARGE OPENING SIDE. 2.) WOOD SCREW SCREWED INTO ABS CLEAN OUT PLUGS IS NOT APPROVED USE TAPPED CLEAN OUT PLUG W/APPROVED SCREW. |
| 01/17/2002 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) YOU HAVE WATER TESTED THE UNDERGROUND THATS ONE SECTION. NOW YOU NEED TO WATER TEST FROM SLAB THRU ROOF - SO THAT NO PIPE OR PITTING SHALL NOT HAVE BEEN SUBJECTED TO A WATER TEST. IN OTHER WORDS FILL THE ENTIRE SYSTEM UP WITH METER, TO THE HIGHET VENT ON THE ROOF. |