| 12/11/2001 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000*1.)CORRECTIONS MADE OK 2.) ABS UNDERGROUND OK WATER TEST OK 3.) OK TO BACKFILL. |
| 12/10/2001 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*1.) MAY NOT REDUCE TRAP ARM-TRAP TO BE SAME SIZE AS TRAP ARM 2.) POINT OF VENT MAY NOT BE BELOW WEIR OF TRAP 3.) FINISH CAPPING OFF EXISTING PIPING TO BE DEMO'D. |