Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T01CM05706
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/07/2002 | FRAMING | Approved | IVRS - Inspection 0000*/ 1) (REINSPECTION) | |
02/06/2002 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) NO GAS TEST PRESSURE 2) ADD 2 X AT FURNACE RETURN 24" ON CENTER 3) LAUNDRY EXHAUST FAN DUCT NOT ATTACHED 4) ANCHOR BOLTS FOR #4 SHEAR WALL NOT INSTALLED, ALSO #1 SHEAR AT GARAGE TO HOUSE 5) GAS LINE AT TOP PLATE, PLATES ARE CUT DEEPLY INSTALL FHA STRAP 6) THA HANGERS IN BEDROOM GIRDER WRAP AROUND TRUSS CORD AND NAIL 7) SHIM ALL 3 PT BEARING TRUSSES |