Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 07/01/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 01/24/2003 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) PARTIAL PENDING COMBUSTION AIR COMPLIANCE 2) OK TO COMPLETE DRYWALL AT FIREPLACE (BOTH) 3) DAMPER AT 1ST FLOOR MUST BE BLOCKED SHUT FOR UNVENTED LOG INSTALLATION |
| 01/23/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) NOTE COMBUSTION AIR REQUIREMENTS PAGE 5 AS WELL AS MANTEC CLEARANCES PAGE 7 FIG. 4.B. YOU MAY WANT TO CONSIDER THE 5" DIA. FLU TO MINIMIZE CLEAN OUTS AS WELL |
| 01/07/2003 |
FRAMING |
|
Partial Approval |
1) PROVIDE GAS PRESSURE TEST 2) PROVIDE SPEC'S FOR GAS LOG 3) PROVIDE MINIMUM 2" CLEARANCE AT 2ND FLOOR FIREPLACE FLUE |
| 12/17/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0950*/ 1) INSTALL FIREPLACE-THEN RECALL INSPECTION |
| 10/16/2002 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) PROVIDE GAS TEST AFTER FIREPLACE 2) STAIRS NOT PER CODE SECTION IRC R314-RISERS VERY BETWEEN 7 AND 8" AND RUNS VERY BETWEEN 10 X 11 1/2" MAXIMUM ALLOWED 3/8" 2) NORTH WALL BOTTOM AND NORTH LAV REQUIRE OUTLETS 3) TUB AND FIREPLACES NOT IN 4) OK TO DRY WALL AND TAPE ALL BUT FIREPLACE CHASES |
| 10/11/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0950*/ 1) HOUSE DRYWALLED WITHOUT APPROVAL OF INTERMEDIATE PLUMBING AND FRAME 2) ELECTRIC WIRES NOT ALLOWED IN RETURN AIR PLENIUM 3) NO GAS PRESSURE TEST 4) ELECTRIC OUTLETS ON NORTH WALL EXCEED 12' ON CENTER 5) PROVIDE PROOF OF PLUMBING DWV WATER TEST PER UPC 712.2 OR EXPOSE ALL PLUMBING AND PROVIDE TEST 6) EXPOSE ALL AREAS OF 9/10002 INSPECTION 7) WOODEN STAIRS EXVEED 3/8" DIFFERENCE FDOR RUN AND RISE AND MAXIMUM RISE OF 7 3/4" 8) FIREPLACES NOT INSTALLED 9) GFCI OUTLET MISSING MASTER BATH RT LAV 10) MECHANICAL DUCT WORK NOT COMPLETE 11) STOPPED INSPECTION |
| 10/10/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) NO PLANS AT SITE |
| 09/10/2002 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) OK TO LATH AND START INSULATION 2) PLEASE RECALL BEFORE DRYWALL 3) ROMEX FEEDER FOR SUP PANEL, PUT IN CONDUIT 4) FHA, BANG PLATES WEST WALL, SOIL AND WATER LINES 5) RETURN DUCT 2ND FLOOR? 6) FIREPLACES 7) TUB CONNECTION WATER TEST AND SHOWER 8) STAIR NOISE ADD SUPPORT 9) AC FEEDER AND AND SUB PANEL FEED BANG PLATE AT STAIR 10) SAFETY GLASS AT STAIR (INSTALL) 11) BOTTOM PLATE 2" VENT 2ND FLOOR BANG PLATE BOTH SIDES, 1ST FLOOR SINK VENT TOP PLATE 12) OUTLET BOXES 2ND FLOOR BATH (LAV) NOT SECURE 13) HANGERS AT STAIR HEADER (LEVEL?) 14) WATER HEATER POWER SOURCE 15) CHECK MAIN WATER SERV. |
| 08/30/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*BOTTOM STRINGERS SUPPORTED BY OSB ONLY. |
| 08/27/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) NAIL PROTECTION AT BORED HOLES 1 1/4" FROM EDGE, CHECK THRU OUT 2) SHEAR PANELS NOT PROPERLY NAILED 3) NEGATIVE FLOW AT ABS DRAINS AND VENTS 4) PROVIDE CLIPS AND STRAPS AT INTERIOR BEARING WALLS 5) STOPPED INSPECTION |
| 08/19/2002 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |