Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T01CM05669

Parcel: 123110920


Addresses:

1448 E LESTER ST


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T01CM05669

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
05/03/2002 FRAMING Approved IVRS - Inspection 0000*
05/02/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) REPLACE SILL PLATE SOUTH WEST CORNER AND HOLDOWN BOLT TO SHORT 2) PROTECT ALL PLUMBING WITHIN 1 1/2 FROM EDGE OF STUD AND ELECTRICAL WITHIN 1 1/4 FROM EDGE OF STUD 3) NO WATER IN VENTS FOR TEST 4) FIREBLOCK AROUND MECHANICAL STAND IN DETACHED BUILDING 5) SHIM HEADERS THROUGHOUT SEE ITME #1 FROM 4/26 INSPECTION 6) SEE ITEM #8, 10, 11, 12 AND 13 FROM PREVIOUS INSPECTION 4/26/02 7) ANCHOR BOLTS LOOSE IN GARAGE AND MISSING NUT 8) GAS PRESSURE TEST FAILED 7 PSI, 10 PSI MINIMUM REQUIRED 9) STOPPED INSPECTION TO MANY NEW AND OLD ITEMS
05/01/2002 FRAMING Denied IVRS - Inspection 0999*
04/26/2002 FRAMING Denied IVRS - Inspection 0950*/ 1) RED HEAD ANCHOR BOLTS LOOSE THROUGHOUT 2) HIP TRUSSES REQUIRE H2.5 CLIPS TO DOUBLE TOP PLATES 3) BLOCK DEFUSER BOOTS ON 3 SIDES 4) ANCHOR BOLTS REQUIRED WITHIN 12" OF SILL PLATE ENDS AND SPLICES 5) ENTRY HALL MISSING 2 ELECTRIC OUTLETS 6) HOLDOWN BOLTS TO SHORT, NUT MUST BE FULLY THREADED 7) SEVERAL TRUSSES NOT CLIPPED 8) REVISE PLAN FOR ADDED 220 VOLT CIRCUIT ON WEST SIDE OF HOME 9) RANGE WIRE NOT SECURE ALSO WALL LOOSE 10) NAIL PROTECT PLUMBING AND ELECTRIC WITHIN 1 1/4" OF WALL STUD SURFACE 11) PROVIDE REVISED AND SIZED GAS PLUMBING PLAN FOR ADDED BBQ 12) ELECTRIC OUTLET NOT ALLOWED UNDER BAR WITH 6" OR MORE OVERHANG 13) NOT ATTIC ACCESS 13) STOPPED INSPECTION, TOO MANY ITEMS
04/03/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*
03/12/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*
03/04/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*