Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T01CM05669
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/03/2002 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
03/12/2002 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection 0000*/ 1) GARAGE AND DROP CEILING TRUSS BRACES NOT IN 2) OK TO DRY IN | |
03/04/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*1.) NO CITY OF TUCSON APPROVED TRUSS DRAWING ON SITE 2.) FREEZE BOARD OT NAILED TO TOP PLATE W B-1BD NAILS SEE B/3 3.) SHEAR WALL 3 MISSING WEST OF PATIO POOL. PROVIDE POSITIVE SHEAR TRANSFOR BETWEEN STUDS. 4.) NAIL ALL STUDS AT CHANNELS AT 24" O.C. ONE NOT NAILED AT ALL 5.) LOOK OUTS & KNEE BRACES NOT INSTALLED PER E/3. 6.) F/3 NUT COMPLETED WITH 7.) QUEST HOUSE NOT READY 8.) FRONT WINDOW HEADER NOT CLIPPED ALSO ENTRY. 9 .) FILL ALL REQUIRED HOLES IN HARDWARE WITH PROPER NAILS.10.) MANY AREA OF ROOF NOT NAILED HAVE SHINERS OR HIGH NAILS 11.) O.S.B. ROOF SHEATING MUST SPAN 2 BAYS ( THREE TRUSSES) REPLACE ALL UNDERSIZE PANELS. STOPPED INSPECTION. |