Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T01CM05664
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/28/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
12/26/2001 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) N/8 NAILS USED IN HANGER AT TRUSS TO GIRDER SHOULD BE N/10 2) NEED TRUSS DRAWINGS ON SITE 3) SHEARWALL PLANS, UNABLE TO FIND SHEAR TRANSFER ON PLAN 4) KITCHEN WALL FRONT SHEAR LENGTH TO BE 4'-6" 5) NEED WATER TEST POTABLE WATER 6) NEED STRUCTUAL DETAIL PORCH ATTACHMENT TO WALL | |
12/21/2001 | FRAMING | Cancelled | IVRS - Ri canceled |