Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T01CM05614
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/15/2002 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
02/12/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) FIRE STOP MUST BE 1" NOMINAL THICKNESS MINIMUM 2) COMPLETE FIREPLACE INSTALL 3) HANG FAU PER ENGINEER SPECS. 4) NAIL SHEARWALL INTERSECTIONS PER PLAN. LADDER BLOCKING NOT PERMITTED | |
02/06/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) SHEARWALL INTERSECTIONS MUST BE NAILED PER DETAIL (10/SD4) 2) ANCHOR PORCH LEDGER TO RESIST PULL-AWAY (H2.5 OR A35) 3) INSTALL TRUSS BRACING PER PLAN (SEE TRUSS CALC'S TRUSS B10) |