Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date |
Description |
Inspector |
Results |
Comments |
| 07/26/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Approved |
IVRS - Inspection 0000* |
| 02/14/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* |
| 02/13/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*TOW MAIN; 4' COLUMNS |
| 02/11/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
PARTIAL 16' |
| 02/08/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*16' |
| 02/07/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*PARTIAL -12' |
| 02/06/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*3L OK MAINTAIN 48 BAR DIAMETER LAP SPLICE, OR, 62 BAR DIAMETERS WHEN 2 BARS IN SAME CELL ARE LESS THAN 2" APART. |
| 02/05/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*KEEP GROUT DOWN 2'-4" FROM TOP OF 2ND LIFT. |
| 02/01/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*PARTIAL IL EXCEPT NEED 30% INCREASE IN LAP LENGTH WHERE 2 BARS ARE IN SAME CELL. |
| 01/31/2002 |
REINFORCED MASONRY PRE-GROUT |
|
Not ready for Inspection |
IVRS - Inspection 0000*NOT READY. |