Permit: T01CM05595

Parcel: 123080600


Addresses:

2626 E HELEN ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
08/13/2002 FRAMING Approved IVRS - Inspection 0000*
08/12/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) RISER OPENINGS CANNOT EXCEED 4" 2) NO OPENING ALLOWED IN GUARD RAILING LARGER THAN 4" 3) CLEANOUT MUST HAVE THREADED CAP TRIM GRADE 4) LABEL ALL CIRCUITS IN SERVICE PANEL 5) PROTECT/BURY GROUND/BOND WIRES 6) SHEET METAL SELF TAPPING SCREWS NOT ALLOWED TO SECURE SERVICE PANEL DEAD FRONT 7) WATER HEATER T&P LINE MUST EXHAUST DOWN 8) CLOTHES DRYER MUST HAVE A 4 PRONG PLUG AND OUTLET 9) DRYER OUTLET MISSING COVER
04/17/2002 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) ITEMS ONE AND TWO FROM 4/15/02 NOT COMPLIED WITH 2) BOND WATER AT WATER HEATER NOT TO T & P LINE IN EXPOSED AREA 3) OK TO INSULATE AND DRYWALL
04/15/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) CUT THRU AT NORTH WEST BATH NOT MADE 2) STAIRS NOT IN FRAME HEADERS MUST BEAR ON TRIMMER-SHIM TIGHT 4) WATER AND GAS BONDING CLAMPS MUST BE ACCESSIBLE. SEE NEC SECTION 250-9 2B 5) FIRE STOP TOP BLOCK DROP BY ELECTRIC SERVICE