Permit: T01CM05569

Parcel: 137055240


Addresses:

1161 W IRVINGTON RD


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T01CM05569

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
06/06/2002 PLUMBING - INTERMEDIATE Approved
05/15/2002 PLUMBING - INTERMEDIATE Denied 1.) 2" COPPER UNDER CONCRETE MUST BE SILVER BRAZED. 2.) MUST USE REQUIRED TEST GAUGE OF 11B INCREMENTS FOR TESTS ABOVE 10LBS 3.) CLOSET RINGS HAVE BEEN SET.
04/22/2002 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1.) ABS DWV OK WATER TEST THRU ROOF OK 2.) COPPER OK PRESSURE OK STRAP WHERE NEEDED 3.) NEED TO SEE CLOSET FLANGES 4.) OK TO COVER WALLS.
04/19/2002 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*NOT READY FOR INSPECTION.
03/11/2002 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*1.) PRE POUR OK 2.) OK FOR CONCRETE.
03/07/2002 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*