Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 06/06/2002 |
PLUMBING - INTERMEDIATE |
|
Approved |
|
| 05/15/2002 |
PLUMBING - INTERMEDIATE |
|
Denied |
1.) 2" COPPER UNDER CONCRETE MUST BE SILVER BRAZED. 2.) MUST USE REQUIRED TEST GAUGE OF 11B INCREMENTS FOR TESTS ABOVE 10LBS 3.) CLOSET RINGS HAVE BEEN SET. |
| 04/22/2002 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*1.) ABS DWV OK WATER TEST THRU ROOF OK 2.) COPPER OK PRESSURE OK STRAP WHERE NEEDED 3.) NEED TO SEE CLOSET FLANGES 4.) OK TO COVER WALLS. |
| 04/19/2002 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000*NOT READY FOR INSPECTION. |
| 03/11/2002 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*1.) PRE POUR OK 2.) OK FOR CONCRETE. |
| 03/07/2002 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000* |