Permit: T01CM05569

Parcel: 137055240


Addresses:

1161 W IRVINGTON RD


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T01CM05569

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
04/04/2002 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection 0000*REINFORCEMENT SPECIAL INSP REPORT REVIEWED & ACCEPTED.
04/02/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*24' E.
04/01/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*PARTIAL DOCK WALLS 24' N N CORNER.
03/29/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
03/28/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*20' EAST WALL.
03/27/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*FRONT COLS.
03/26/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*16' E.
03/25/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
03/22/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
03/21/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000* 12' EAST.
03/20/2002 REINFORCED MASONRY PRE-GROUT Partial Approval TOW WEST 8' EAST 28'TOW NORTH.
03/19/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*TOW SW 8' E
03/15/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*T0W SOUTH SIDE 28' WS; 24' N.
03/13/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*TOW SE 28' SW.
03/12/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000* PARTIAL 24' WEST; 24' NW.
03/11/2002 REINFORCED MASONRY PRE-GROUT Partial Approval PARTIAL PER LEE RAY
03/08/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*20' NORTHSIDE 20' WEST.
03/07/2002 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection 0999*1/2" SPACING NOT MAINTAINED FROM OF BLOCK. 1" SPACE BETWEEN VERTICALS NOT MAINTAINED.
03/06/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*16' NORTH WALL, 20' SOUTH WALL.1.) DONT FORGET 45 AT EAST END OF NORTH WALL. 2.) PLEASE REMEMBER TO MAINTAIN 1" SPACING BETWEEN BARS. 3.) PROVIDE CERTIFICATION FOR OF NELSON STUDS TO TOP PLATE.
03/05/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*IL LOADING DOCK; 12' NE; 16' NW;16' SE CORNER.
03/04/2002 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection 0000*
03/01/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*16' SOUTH; 6'SW' 12' NW'8'
02/27/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*12'5; 8' W, 8' FOR 1/2 N. YOU MUST KEEP VERTICALS REAR CENTER OF OF CELL AND MAINTAIN MINIMUM 1" SEPERATION.
02/26/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*8' SOUTH & 1/2 OF WEST.
02/25/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*OK TO GROUT NORTH & EAST (1ST LIFT)
02/22/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*4' SOUTH, 4' WEST