Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/15/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 01/14/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) CORRECT OVER NOTCHED EXTERIOR BEARING STUDS |
| 01/11/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) CORRECT OVER NOTCHING OF EXTERIOR 2 X 4 BEARING STUDS 2) FHA STRAP TOP PLATES AT GAS MAIN RISER |
| 01/10/2002 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) SEE PREVIOUS INSPECTION DTD 1-9-2 NOTES #2, 3 AND 6 |
| 01/09/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) NO WATER TEST ON TOP OUT 2) PROTECT ELECTRICAL WIRES TOP PLATE AT GARAGE RACE WAY 3) PROTECT ELECTRIC WIRE AT DOUBLE TOP PLATE LEFT SIDE OF DOOR ENTRY TO LAUNDRY ROOM 4) SECURE GAS LINE AT GREAT ROOM BY 90 DEGREE TURN 5) GROUND PANCAKE BOX AT MASTER BEDROOM 6) FRAMING OK WILL APPROVE WHEN ALL TRADES ARE COMPLETE |