Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 11/26/2001 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000*1.) ABS DWV UNDERGROUND OK WATER TEST TO TEN FEET OK 2.) OK TO BACKFILL 3.) WILL CHECK BACK PITCHED REVENT ON INTERMEDIATE 4.) PLUMBER: REMEBER, A DOUBLE SANTEE MAY BE USED WHEN THE BARREL OF THE FITTING IS AT LEAST 2 TWO PIPE SIZES LARGER THAN THE LARGEST INLET. USE A ABLE COMBO. OR A FIG. 5-. |
| 11/20/2001 |
PLUMBING - ROUGH, SOIL |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 11/20/2001 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*1.) WATER CLOSETS NOT INSTALLED PER PLAN. 2.) PLAN CALLS FOR 4" OVER SIZED VENT OK IF YOU WANT. 3.) WATER TEST REQ'D TO MINIMUM TEN FEET HEAD. |