Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T01CM05486

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
03/20/2002 ELECTRIC - INTERMEDIATE Approved 1.) INSPECTION ON 2 CAR DETACHED GAR. OK THANKS
02/04/2002 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection 0000*APPROVED NOTE DETACHED GARAGE NOT INCLUDED.
01/30/2002 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0245*NOTES 1.) REMOVE LOW VOLTAGE DOOR BELL WIRING FROM THE INTERIOR OF THE 110V J box 2.) INSTALL GROUND WIRE PIGTAILS FOR ALL SWITCHES. BOXES WITH THE METAL GROUND SRAP DO NOT NEED A PIGTAIL. 3.) INSTALL A "FAN" BOX IN 2ND FLR. BEDROOM CIELING. 4.) PROVIDE FLEX CONDUIT SLEEVE FOR A/C FEEDER ROMEX OR INSTALL 'J' BOX IN WALL. CABLE CANNOT BE EXTENDED UNPROTECTED TO UNIT.