Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 03/20/2002 |
ELECTRIC - INTERMEDIATE |
|
Approved |
1.) INSPECTION ON 2 CAR DETACHED GAR. OK THANKS |
| 02/04/2002 |
ELECTRIC - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000*APPROVED NOTE DETACHED GARAGE NOT INCLUDED. |
| 01/30/2002 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0245*NOTES 1.) REMOVE LOW VOLTAGE DOOR BELL WIRING FROM THE INTERIOR OF THE 110V J box 2.) INSTALL GROUND WIRE PIGTAILS FOR ALL SWITCHES. BOXES WITH THE METAL GROUND SRAP DO NOT NEED A PIGTAIL. 3.) INSTALL A "FAN" BOX IN 2ND FLR. BEDROOM CIELING. 4.) PROVIDE FLEX CONDUIT SLEEVE FOR A/C FEEDER ROMEX OR INSTALL 'J' BOX IN WALL. CABLE CANNOT BE EXTENDED UNPROTECTED TO UNIT. |