Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T01CM05486
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/04/2002 | FRAMING | Approved | IVRS - Inspection 0000* FRAMING ALREADY FINISHED. | |
01/30/2002 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*1.) FIX SHINERS @ EXT SHEATING/STUD 2.) SUPPORT 2 X 4 C J OVER KITCHEN PANTRY ( WEST SIDE OF KITCHEN AT MID SPAN. 3.) COMPLETE HARDWARE (HOLD DOWNS) 4.) SUPPORT 2 X 4 C J'S @ MID SPAN 5.) PROVIDE AB'S @ SW3 6.) RENAIL SHEAR WALLS WHER NAILS ARE OVER DRIVEN 7.) RE NAIL SHEARWALLS WHERE NAILS ARE LESS THAN 3/8" FROM EDGE OF SHEET. 8.) PROVIDE FIRE BLOCK @ DRYER VENT @ 1ST FLOOR CEILING 9.) BLOCK FOR SHEET ROCK @ SW-1 |