Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/07/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 01/03/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) TWO BROKEN TRUSSES IN LAUNDRY ROOM, CHECK ALL 2) NEED CABLE PULLED GARAGE 3) TRUSS SHOP DRAWINGS, DON'T ALLOW ENOUGH TRUSSES TO FINISH GABLE 2 X 6 OVER FRAMING NOT TO EXCEED 6' 4) FINISH C.C. PLY WOOD AT REAR PORCH 5) MISSING NAILING REAR GABLE 6) MISSING WIND BRACES REAR WALL 7) TIE #1 SHEARWALLS TO END TRUSSES F A.35 AT 24" ON CENTER 8) INSTALL ALL LATERAL BRACING |