Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 01/07/2002 |
ELECTRIC - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000*OK CABLE DROP, NO POWER CLEANRANCE YET. PLEASE SEE FORM FOR TEMP POWER. |
| 01/04/2002 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0245*1.) RE INSTALL ROMEX INSIDE OF STUDS, 2.) VERIFY WATER & GAS BONDING. |
| 01/03/2002 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0245*UNIT #2 1.) RE-ATTACH BOXES FOR BATHROOM LIGHT, KITCHEN OUTLET FOR HOOD, RANGE OUTLET ROMEX, 2.) SUPPORT ROMEX HOME RUNS DOWN WALL AT SERVICE PER N.E.C. ALSO STAPLE ROMEX FOR DRYER OUTLET WITHIN 12" OF BOX. 3.) ROMEX FOR WATER HTR AND FURNANCE SHOULD TERMINATE IN BOXES OR HAVE FLEX INSTALLED AND SECURED TO STUDS PRIOR TO DRYWALL INSTALL. |
| 12/28/2001 |
ELECTRIC - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000* |