Permit: T01CM05442

Parcel: 111071280

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
01/07/2002 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection 0000*OK CABLE DROP, NO POWER CLEANRANCE YET. PLEASE SEE FORM FOR TEMP POWER.
01/04/2002 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0245*1.) RE INSTALL ROMEX INSIDE OF STUDS, 2.) VERIFY WATER & GAS BONDING.
01/03/2002 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0245*UNIT #2 1.) RE-ATTACH BOXES FOR BATHROOM LIGHT, KITCHEN OUTLET FOR HOOD, RANGE OUTLET ROMEX, 2.) SUPPORT ROMEX HOME RUNS DOWN WALL AT SERVICE PER N.E.C. ALSO STAPLE ROMEX FOR DRYER OUTLET WITHIN 12" OF BOX. 3.) ROMEX FOR WATER HTR AND FURNANCE SHOULD TERMINATE IN BOXES OR HAVE FLEX INSTALLED AND SECURED TO STUDS PRIOR TO DRYWALL INSTALL.
12/28/2001 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*