Permit: T01CM05392

Parcel: 133541000

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T01CM05392

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
01/14/2002 FRAMING Approved IVRS - Inspection 0000*
01/11/2002 FRAMING Denied IVRS - Inspection 0999*
01/10/2002 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) SEE PREVIOUS INSPECTIONS DTD 1-9-2 NUMBERS 1, 2 AND 6
01/09/2002 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) PROVIDE IGGA STRAP WITH 6-16D NAILS EACH SIDE TOP PLATE NOTCHED 50 PERCENT OR MORE AT GARAGE 2) PROTECT ELECTRICAL AT GARAGE 3) MST 37 AT GARAGE NOT NAILED PROPERLY 4) NAIL CLIP AT TRUSS EAST WALL GARAGE 5) SECURE PEX AT MASTER CLOSET 6) AT UPSTAIRS HALL BATH MOVE ELECTRICAL WIRES AWAY FROM HOT WATER COPPER LINE 7) PROVIDE 1" CLEARANCE AT FURNACE AND FLOOR FROM FLUE TO ABS VENT 8) OK TO INSULATE