Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/14/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 01/11/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 01/10/2002 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) SEE PREVIOUS INSPECTIONS DTD 1-9-2 NUMBERS 1, 2 AND 6 |
| 01/09/2002 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) PROVIDE IGGA STRAP WITH 6-16D NAILS EACH SIDE TOP PLATE NOTCHED 50 PERCENT OR MORE AT GARAGE 2) PROTECT ELECTRICAL AT GARAGE 3) MST 37 AT GARAGE NOT NAILED PROPERLY 4) NAIL CLIP AT TRUSS EAST WALL GARAGE 5) SECURE PEX AT MASTER CLOSET 6) AT UPSTAIRS HALL BATH MOVE ELECTRICAL WIRES AWAY FROM HOT WATER COPPER LINE 7) PROVIDE 1" CLEARANCE AT FURNACE AND FLOOR FROM FLUE TO ABS VENT 8) OK TO INSULATE |