Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/17/2002 | FRAMING | Approved | IVRS - Inspection 0000*/ 1) REINSPECT | |
01/16/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) SECURE GAS LINE 2) CLIP MISSING AT TRUSS ABOVE STAIRS 3) CLIPS MISSING 2 TRUSSES 2ND FLOOR SOUTH SIDE 4) SUPPORT DUCT WORK HALL WAY 2ND FLOOR | |
01/11/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) FHA STRAP TOP PLATES AT GAS MAIN AND ELECTRIC HOME RUNS 2) BLOCK FURNACE PLENIUM-SAME AS DUCT BOOT 3) SOLID BLOCK FLOOR TRUSS AT MST IN REAR GARAGE CEILING 4) CORRECT DRYER VENT CONNECTION AT EXTERIOR BOOT 5) SHIM 2-2 X 4 POST AT EXTERIOR-REAR GARAGE WALL 6) MOVE ELECTRIC WIRES OFF FLUE-ABOVE GARAGE FURNACE PLENIUM 7) ADD H2.5'S AT DOUBLE FLOOR TRUSSES IN GARAGE 8) STRAP ALL TOP PLATES AT FRONT BAY 9) STOPPED INSPECTION AFTER FRONT HALF OF 1ST FLOOR | |
12/26/2001 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* |