Permit: T01CM05391

Parcel: 133541620

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T01CM05391

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
01/17/2002 FRAMING Approved IVRS - Inspection 0000*/ 1) REINSPECT
01/16/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) SECURE GAS LINE 2) CLIP MISSING AT TRUSS ABOVE STAIRS 3) CLIPS MISSING 2 TRUSSES 2ND FLOOR SOUTH SIDE 4) SUPPORT DUCT WORK HALL WAY 2ND FLOOR
01/11/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) FHA STRAP TOP PLATES AT GAS MAIN AND ELECTRIC HOME RUNS 2) BLOCK FURNACE PLENIUM-SAME AS DUCT BOOT 3) SOLID BLOCK FLOOR TRUSS AT MST IN REAR GARAGE CEILING 4) CORRECT DRYER VENT CONNECTION AT EXTERIOR BOOT 5) SHIM 2-2 X 4 POST AT EXTERIOR-REAR GARAGE WALL 6) MOVE ELECTRIC WIRES OFF FLUE-ABOVE GARAGE FURNACE PLENIUM 7) ADD H2.5'S AT DOUBLE FLOOR TRUSSES IN GARAGE 8) STRAP ALL TOP PLATES AT FRONT BAY 9) STOPPED INSPECTION AFTER FRONT HALF OF 1ST FLOOR
12/26/2001 FRAMING Not ready for Inspection IVRS - Inspection 0000*