Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T01CM05334
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/10/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
12/06/2001 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) REMOVE BENT NAILS AT HANGERS 2) MOVE PEX WATER LINE 12" FROM CAN LIGHT AT MASTER BATH 3) A35'S AT 2 X 4 CONNECTION TO GIRDER TRUSS AT MASTER BEDROOM 4) REMOVE BLOCKS BETWEEN TRUSSES AT GIRDER AND CORRECT NAILS | |
12/05/2001 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) NO PLANS NO PERMIT ON SITE | |
12/04/2001 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) NEED TRUSS SHOP DRAWINGS 2) TRUSS TO GIRDER TRUSS HANGER NAILS ALL BENT OVER, HANGER NAILS ARE BEING SHOT IN WITH A NAIL GUN 3) GARAGE SHEAR NOT TIED TO TRUSSES CANNOT FIND SHEARWALL PAGE THAT RELATES TO SHEAR TRANSFER DETAILS 4) MOVE PEX WATER AWAY FROM REAR BATH CAN LIGHT 5) CANNOT FIND A DETAIL TRUSS TO GIRDER TRUSS HANGER TYPE 6) GAS TEST OK |