Permit: T01CM05287

Parcel: 141147370

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
12/17/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
12/14/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) STRAP NON-CABIN TIED TOP PLATES AT FRONT ENTRY DOOR 2) BLOCK ROOF PLY AT PATIO ROOF CONNECTION A AND B