Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T01CM05280
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/02/2002 | FRAMING | Approved | IVRS - Inspection 0000* | |
12/31/2001 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) DUCT LOOSE AT 2ND FLOOR 2) SECURE WATER HEATER FLUE 3) PAPER AT FURNACE FLUE (ROOF) 4) ELECTRIC AT GARAGE | |
12/27/2001 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) MISSING FIRE BLOCKING AT LAUNDRY 2) BLOCK DEFFUSER AT 1ST FLOOR BATHROOM 3) CORRECT STRAPS AT GARAGE FORM 2ND FLOOR SHEARWALLS 4) COMPLETE ELECTRIC AT STAIR-WELL 5) SEAL AIR PLENUM 6) LUGS AT LEDGER 6) LOOSE DUCT AT 2ND FLOOR BOTH 7) NEED 1" CLEARANCE AT WATER HEATER FLUE | |
12/26/2001 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* | |
12/21/2001 | FRAMING | Denied | IVRS - Inspection 0999*1.) SECURE GAS LINE IN GARAGE 2.) EAST SIDE 4 X6 POST REC 64 MISSING 2 NAIL. 3.) GLB AT GARAGE PROVIDE ENGINERIAL FOR HOLES DRILLED THROUGH GLU LAMB. 4.) FIRE BLUCKING MISSING AT FURNACE AREA. 5.) ELECTRICAL NOT COMPLETE UNDER STAIRS 6.) ELECTRICAL WIRES HANGING IN MASTER BATH AREA. STOPPED INSPECTION HAVE SUPERVISOR WALK HOUSE BEFORE RECALLING. |