Permit: T01CM05272

Parcel: 119214020

Inspection Status: Partial Approval

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T01CM05272

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Partial Approval

Date Description Inspector Results Comments
11/19/2001 PLUMBING - INTERMEDIATE Partial Approval
11/16/2001 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*1.) NO PRESSURE TEST ON PEX.
11/15/2001 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*1.) NO PRESSURE TEST ON PEX PIPE CUT TO WASHER BOX 2.) TRAP ARM FOR WASHER BOX IS NOT TWO PIPE DIAMETERS FROM WEIR OF TRAP TO POINT OF VENT.
11/14/2001 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*1.) PEX PIPING REQUIRES STRAPPING 3' MAX HORIZONTAL 2.) BUNDLEING OF PEX NOT PERMITTED. MAINTAIN SEPARATION, ESPECIALLY HOT FROM COLD. 3.) ABS DWV OK WATER TEST OK 4.) PEX REQUIRES STRAPS 5.) CLOSET RINGS OK 6.) TUBS OK.