Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/04/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 01/25/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) NO CITY OF TUCSON APPROVED TRUSS DRAWINGS ON SITE 2) SEVERAL TRUSSES WRAPPED AND RACKED STRENGTHEN OR PROVIDE TRUSS ENGINEERS CERTIFICATION OF MINIMUM COMPLIANCE 3) VERTICAL BEARING LEGS OF 5 TRUSSES HAVE BEEN TRIMMED TO LESS THAN 3 1/2" IN CROSS SECTION. PROVIDE APPROVED TRUSS MANUFACTURERS REPAIR 4) MANY EXTERIOR SHEETS OF O.S.B. NOT NAILED |