Permit: T01CM05268

Parcel: 122162610


Addresses:

3737 E PIMA ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
02/04/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
01/25/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) NO CITY OF TUCSON APPROVED TRUSS DRAWINGS ON SITE 2) SEVERAL TRUSSES WRAPPED AND RACKED STRENGTHEN OR PROVIDE TRUSS ENGINEERS CERTIFICATION OF MINIMUM COMPLIANCE 3) VERTICAL BEARING LEGS OF 5 TRUSSES HAVE BEEN TRIMMED TO LESS THAN 3 1/2" IN CROSS SECTION. PROVIDE APPROVED TRUSS MANUFACTURERS REPAIR 4) MANY EXTERIOR SHEETS OF O.S.B. NOT NAILED