Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T01CM05265
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/07/2002 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection 0000*1.) CORRECTIONS MADE OK ABS WATER TEST OK PEX PRESSURE TEST OK 2.) CLOSET FLANGES OK 3.) TUBS OK 4.) OK TO COVER ALL AREAS. | |
06/04/2002 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999*1.) SEE 313.2. ITEM NUMBER 2 SEPARATION OF HOT & COLD WATER DISTRIBUTION PIPING HOT & COLD WATER PIPING MAY NOT BE BUNDLED TOGETHER. 2.) CONTRACTOR TO PAY REINSPECTION FEE. | |
06/03/2002 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999*1.) PROVIDE INSTALLATION STANDARD ALLOWING PEX PIPING TO BE BUNDLED TOGETHER. 2.) DO NOT COVER UNTIL THIS ISSUE IS RESOLVED. | |
05/31/2002 | PLUMBING - INTERMEDIATE | Denied | BOTH GAS LOCKED NO ACCESS. | |
05/30/2002 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999* 1.) GAS PIPING OK PRESSURE TEST OK 2.) ABS NEEDS WATER TEST THROUGH ROOF. | |
05/22/2002 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000*1.) PROVIDE DOCUMEUTATION FOR COMPLETION OF HCS CONNECTION 2.) SEE NOTE #3 1/7/02 WHY WASNT I CALLED FOR A PRE-POUR INSPECTION? |