Permit: T01CM05265

Parcel: 117144390


Addresses:

776 S MEYER AV


Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T01CM05265

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
05/30/2002 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection 0000*
05/22/2002 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0999*1.) NEED FHA STRAPS AT MOST 2X WALLS 2.) MUST UTILIZE ROMEX CONNECTORS FOR ALL BOXES (EXCEPT THE 2X4 NOMINAL SWITCH BOX.) 3.) THE TYRAPS MUST BE CINCHED TIGHT 4.) IF ROMEX IS RUN IN CAVITY RECESS OF METAL 2 X4 THEN IT MUST BE CINCHED DIRECTLY ON CENTER THROUGH OUT LENGTH OF RUN 5.) INSTALL ALL BOXES.