Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
Permit Number - T01CM05264
Inspection Description - MECHANICAL - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/17/2002 | MECHANICAL - FINAL | Approved | IVRS - Inspection 0000* | |
09/13/2002 | MECHANICAL - FINAL | Partial Approval | IVRS - Inspection 0000*B-I VENT PIPE TOUCHING REFIRGERANT LINE INSULATION IN FRONT OF CASED EVAPORATOR COIL. 2.) CONDENSATE DRAIN PIPING (PVC) HORIZONTAL SECTION IN FRONT OF IN FURNACE. RELOCATE (LOWER) TO CLEAR ACCESS FOR REMOVAL AT FRONT OF PANEL. CORRECT/RECALL. |